Version 5.01

Release Date: 15 June 2022

 

INFORMATION: Please read these release notes carefully before updating.

 


CAUTION: Take screenshots of your current controller settings including all setup and calibration data including input and output function assignments and invert status as after loading this software your controller might reset to default settings or controller settings might change. 

 

https://docs.masso.com.au/wiring-and-setup/save-and-load-settings

 


CAUTION: The below steps need to be followed if updating your controller from any other software version apart from version 5.0 

 


Update Process

 

  1. Make a backup of your machine settings
  2. Save and print a copy of your printable file for checking settings after the update.
  3. Copy the software file to your flash drive inside the MASSO folder
  4. Repower your MASSO controller and access the software load screen:

      • MASSO Touch:  Tap the screen during startup

      MASSO G3: Press F1 on the external keyboard

  5. Select the new software version and press Enter
  6. Wait for software to complete the update, approximately 45 seconds
  7. Press the Escape button to exit the software load screen.
  8. Use your Printable file to check your settings, correct if needed.

 

The Update is complete.

 


New in Version 5.01

 


Machine Homing Enhancement

 

  • The Home button next to the JOG buttons has been removed.

  • To start homing, double-click the flashing HOME indicator on the screen.

     


Resume Machining from G-Code File Editor

 

  • Added the ability to resume machining directly from a selected line in the G-code file editor.

     


M66 – Input Signal Control in G-code

 

  • Added support for M66, allowing external input signals to be used in G-code.

     

Learn more: M66 Documentation - CLICK HERE

 


M85 & M86 – Automatic Door Control

 

  • Added M85 and M86 for automatic door open and close via G-code.

  • Fully integrated with automatic tool change operations.

     

Learn more: M85 & M86 Documentation - CLICK HERE

 


Improvements & Bug Fixes

 


Backlash Logic Improvements

 

 

IMPORTANT:

 

  • Significant improvements to backlash logic.

  • If you use backlash compensation, this update is highly recommended.
     


Spindle Control Enhancements

 

  • Added RPM acceleration and deceleration support for Step/Dir and PWM spindle control modes.
     


Plasma Enhancements
 

  • Fixed inch-mode voltage conversion on the F2 screen.

  • Added a torch offset option when G200 is disabled.
     


Scribe Tool Fixes

 

  • Fixed an issue where the scribe ON/OFF function did not operate correctly.
     


Conversational Wizard Fixes

 

  • Various usability improvements and bug fixes.
     


Axis Calibration Wizard Fixes

 

  • Fixed an issue affecting inch mode operation.
     


G-code File Editor Fixes

 

  • Fixed an issue that prevented saving a file more than once without reopening it.
     


Machine JOG Feedrate on Power-Up

 

  • Default JOG feedrate is now set to 10% on power-up.

  • Helps reduce the risk of accidental crashes before homing.
     


WaterJet Enhancements

 

  • Improved WaterJet logic for better control and reliability.
     


On-Screen Keyboard Safety Improvement

 

  • In MDI mode, the ENTER key is now disabled on the on-screen keyboard.

  • Commands must be executed using the RUN button.

  • Prevents accidental execution when using Backspace.

     


Drilling Cycle Enhancements

 

  • Fixed Jump to Line issues with drilling cycles for smoother operation.