Read these notes before updating. Your settings may reset to defaults or change, so save them and take screenshots of all setup and calibration data, including input and output assignments and invert status. See Save & Load Settings.
WARNING
Updating from version 4 or earlier:
All tool data on the F4 screen is erased. Re-enter it before using the machine.
The mill linear tool changer uses new logic. Reassign all its inputs and outputs and enter its calibration data in the F1 tool changer settings before using the machine.
Updating from 5.00 or 5.01 does not need these steps.
How to update
1
Back up your machine settings, and save and print the printable settings file so you can check settings afterwards.
2
Copy the software file into the MASSO folder on your USB flash drive.
3
Power-cycle MASSO and open the software load screen: on MASSO G3 Touch, tap the screen during start-up; on MASSO G3, press F1 on the keyboard.
4
Select the new version and press Enter. The update takes about 45 seconds.
5
Press Esc to leave the load screen.
AFTER UPDATING
Compare your settings with the printed file and correct anything that changed.
What's new
NEWSpindle and coolant stop on feed hold
A new option in Main Spindle Settings. When on, the spindle and coolant turn off when you press Feed Hold and restart when you press Cycle Start.
NEWJump to Line prompt
An on-screen prompt guides you through resuming a job safely with Jump to Line.
Improvements and fixes
IMPROVEDSubprogram files
Subprogram files must now be in the same folder as the main program.
IMPROVEDJog feed rate at power-up
Jog feed rate starts at 1% at power-up, to reduce the risk of a crash before homing.
IMPROVEDMotor alarms
Motor alarm messages clear from the screen when E-Stop is pressed.
IMPROVEDMPG handwheel
Smoother, more precise handwheel motion.
IMPROVEDPlasma auto voltage
Better voltage sampling and cut voltage detection at the start of a plasma cut.
IMPROVEDEMCO lathe tool turret
More accurate and reliable turret homing.
IMPROVEDWaterjet Jump to Line
Better cut resumption on waterjet.
IMPROVEDDoor logic
Better door open/close handling and safer auto start/stop.
FIXEDAir pressure alarm
The low air pressure alarm did not show at power-up.