Version 5.06
Release Date: 19 October 2023
https://docs.masso.com.au/wiring-and-setup/save-and-load-settings
https://docs.masso.com.au/wiring-and-setup/save-and-load-settings
Update Process
- Make a Backup of your machine settings
- Save and print a copy of your Printable File for checking settings after the update.
- Copy the software file to your flash drive inside the MASSO folder.
Repower your MASSO controller and access the software load screen:
• MASSO Touch: Tap the screen during startup
• MASSO G3: Press F1 on the external keyboard
- Select the new software version and press Enter.
Wait for the update to complete (approximately 45 seconds).
Press Escape to exit the software load screen.
Use your Printable File to check and correct settings if required.
The Update is complete.
New in Version 5.06
G38.7 – Centre Probing Cycle
Added support for G38.7 to locate the centre point using G-code commands.
Learn more: G38.7 Centre Probe Cycle Documentation
Tower Light Flashing
The green tower light now flashes to attract attention during:
M00(Program Stop)M01(Optional Stop)Manual tool change requests
Settings File Name Management
Settings files can now be renamed for easier organisation.
File names can start with examples such as:
MASSO_5-Axis_ToolsMASSO_Mill_Settings
Additional text or numbers can be added for clearer identification.
Improvements & Bug fixes
Motor Alarm Logic Enhancement
Motor alarms are now checked before homing, improving safety.
Spindle Improvements
Improved spindle Auto On/Off logic.
Fixed an issue where the spindle could start unintentionally during probing.
Jump to Line Enhancements
Improved reliability and fixed multiple bugs.
Additional logic improvements for WaterJet Jump to Line.
G-code File Editor Fixes
Fixed issues related to editing and saving files.
Multi-Head System Enhancements
Improved logic and screen button behaviour when switching heads.
Axis Slaving Enhancements
Optimised axis slaving logic for better synchronisation.
Probing Offset Fix
Fixed a miscalculation bug introduced in v5.04b that caused incorrect probing offsets.
If offsets were adjusted in v5.04b, restore them to the values used in v5.03.
5-Axis Software Startup Fix
Fixed an issue where the 5-axis version would not start after upgrading from a 3-axis system.
Screenshot Capture Performance
Reduced screenshot save time from 15 seconds to under 1 second.
Umbrella Tool Changer Fix
Fixed an issue where the tool changer could move to the incorrect tool slot after homing.
Spindle Start Issue Fix
Fixed the intermittent spindle start issue present in v5.04b and v5.05.
Spanish
French
German
Simplified Chinese