Version 5.11

MASSO G3 software
Version 5.11
Released 2 September 2025
CAUTION
Read these notes before updating. Back up your settings and save and print the printable settings file, so you can check every setting after the update. See Save & Load Settings.

How to update

1
Back up your machine settings, and save and print the printable settings file.
2
Copy the software file into the MASSO folder on your USB flash drive.
3
Power-cycle MASSO and open the software load screen: on MASSO G3 Touch, tap the screen during start-up; on MASSO G3, press F1 on the keyboard.
4
Select the new version and press Enter. The update takes about 45 seconds.
5
Press Esc to leave the load screen.
AFTER UPDATING
Compare your settings with the printed file and correct anything that changed.

What's new

NEWCutter compensation (G40, G41, G42)

Added for Advanced and Legacy controllers. MASSO adjusts the toolpath for the actual tool diameter, so you can run the same program with different tools, compensate for wear or regrinding by updating the diameter in the tool table, and get higher precision without regenerating CAM output.

G40 – cancel  ·  G41 – left  ·  G42 – right

INFORMATION
The G-code needs proper lead-in and lead-out moves so compensation can be applied smoothly.
Cutter compensation lead-in and lead-out
NEWAxis output testing

Integrated Diagnostics now has axis output test buttons on the Essential, Core and Advanced levels, to test and verify axis outputs directly from the controller. See Axis Testing.

Integrated Diagnostics axis output test