Controller Alarms
This page explains the common alarms displayed by MASSO and how to clear them.
E-Stop Alarm
An E-Stop alarm is shown when MASSO starts.
Press and release the E-Stop button to confirm it is working
This will clear the alarm
The alarm will also activate if the E-Stop button is pressed during operation
Homing Alarm
This alarm indicates the machine has not been homed.
Home the machine to clear the alarm
If a Homing Error occurs, something went wrong during homing
• Re-home the machine to clear the alarm
Door Alarm
This alarm indicates the cabinet door is open.
Close the door to clear the alarm
The machine can be configured to automatically stop and start when the door is opened or closed
G2 Note:
If using a G2, a door alarm output must be assigned even if no door is fitted.
Setting this input to Logic Low will remove the alarm.
Soft Limit Alarm
Each axis has defined travel limits in its axis settings.
If a commanded move exceeds these limits, a Soft Limit alarm is triggered
Issue a valid move within limits to clear the alarm
Hard Limit Alarm
Triggered by homing sensors.
Usually caused by a mechanical or wiring fault
Find and fix the cause of the fault
Home the machine to clear the alarm
Probing Alarm
Occurs during a probing cycle if:
No probe signal is received within the specified distance, or
The probe is already active when probing starts
To clear:
Issue a new probing command
Ensure the probe is not active
Use a valid probing distance
Tool Error Alarm
This alarm occurs if an unsupported tool number is selected:
G3 / MASSO Touch: Tool number greater than 118
G2: Tool number greater than 31
Motor Alarm
Triggered when a Stepper or Servo drive enters an alarm state.
MASSO will enter Feed Hold and stop the spindle
The drive must support alarm signalling and be correctly wired
To clear:
Clear the fault on the drive
Home the machine to clear the alarm in MASSO
Lubricant Low Alarm
If a lubricant vessel with an alarm output is connected:
A Lubrication Low alarm is displayed when the level is low
Top up the lubricant
The alarm clears automatically
Air Pressure Low Alarm
Triggered when air pressure drops below the sensor threshold.
Alarm input changes to High
Air Pressure Low alarm is displayed
To clear:
Restore air pressure (input returns to Low)
Home the machine
Use Jump to Line to resume machining
Spindle Alarm
Monitors the spindle alarm output from the VFD.
If the input goes High, MASSO enters Feed Hold
Spindle Alarm is displayed
To clear:
Home the machine
Spindle Coolant Pulses Alarm
Monitors coolant flow using pulse input.
Requires at least 1 pulse every 10 seconds while the spindle is running
If no pulse is detected:
MASSO enters Feed Hold
Spindle Coolant Alarm is displayed
To clear:
Home the machine
Spindle Coolant Flow Alarm
Monitors coolant flow using a continuous signal.
Alarm triggers if the input stays High for 10 seconds or more while the spindle is running
MASSO enters Feed Hold
To clear:
Home the machine