MASSO Documentation

List of Configurable Inputs

Different functions can be assigned to inputs in the F1-Settings screen. These can be used to set up things such as:


  • Homing sensors.
  • Input buttons for cycle start.
  • Input buttons to automatically load gcode files from USB Flash drive.
  • Tool changer sensor inputs.


INFORMATION: All input signals can be easily inverted by selecting the input in the INPUTS list and pressing the space-bar key on the keyboard to invert the input signal. These settings are automatically saved.


INFORMATION: All Masso inputs are optically isolated and trigger with inputs from +5v to +24v 


INFORMATION: Some inputs used for external buttons require the button to remained pressed for 1 second before the input is accepted. This is to safe guard against accidental operation.




List of Configurable Inputs


  • X, Y, Z, A, B - Home Sensor Input.
  • Door Sensor Input.
  • Probe Input Signal.
  • Home Machine Input.
  • Go to Home Machine Input
  • Go to Parking Position
  • Cycle Start Button Input.
  • Cycle Stop Button Input.
  • Chuck Clamp/Unclamp Input.
  • Coolant Mist On Input.
  • Coolant Flood On Input.
  • Coolant Mist & Flood Off Input.
  • Plasma - Torch Touch Signal Input.
  • Plasma - Plasma Arc OK Signal.
  • Plasma - Torch Breakaway Signal.
  • Jog/Rapid X+ & X- Inputs.
  • Jog/Rapid Y+ & Y- Inputs.
  • Jog/Rapid Z+ & Z- Inputs.
  • Jog/Rapid A+ & A- Inputs.
  • Jog/Rapid B+ & B- Inputs.
  • Jog/Rapid Mode Input.
  • Autoload G-Code (1, 2, 3, 4, 5, 6) Inputs.
  • Tool Changer - Inputs.
  • X, Y, Z, A, B Motor Alarm Input.
  • Lubricant Alarm Input.
  • Axis Motor Drive Alarm Input.
  • Spindle Drive Alarm Input.
  • Tool Setter Input.
  • Air Pressure Low Alarm Input.
  • Spindle Coolant Pulses Alarm
  • Spindle Coolant Flow Alarm Input.
  • Gcode Rewind Button Input.