S - Speed / Intensity

S sets either the spindle speed or the laser intensity, depending on the active tool and mode.

Syntax
S__
Spindle
RPM
Laser
0–1000 = 0–100%

1. Meaning of S

ToolS value
SpindleSpindle speed in RPM. Usually used with M3 or M4 to start the spindle.
LaserLaser power as a PWM value from 0 to 1000, equal to 0 to 100% output.

2. Examples

CodeResult
N10 S10000Spindle: sets 10,000 RPM. Usually followed by M3 or M4, on the same line or the next, to start the spindle.
N10 S500Laser: sets 50% output.