M666 – Plasma – Turn THC Function Off
This command is used to switch OFF the THC automatic Z axis control function in the plasma version.
Syntax & Parameters
- M666
Example program
N10 M666 N20 G1 X1 F1000
The above program switches Off the THC function.
This Gcode does not take effect until the next axis move.