Tower Lights
Tower lights can be connected to MASSO outputs to provide a visual indication of machine status.
| Name | State | Description |
|---|---|---|
| Red | Flashing | Major alarm e.g: E-Stop |
| Yellow | Flashing | Minor alarm e.g: Door is open or Homing required |
| Green | Solid | Program running normally |
| Green | Flashing | User action required e.g: M00, M01, Manual tool change |