Dust Hood

WARNING – IN DEVELOPMENT
Stand-alone dust hood logic is for MASSO G3 and MASSO G3 Touch only and is in development in Version 6 Beta software. In the current main release, 5.13, the dust hood is part of the tool changer logic.

The dust hood is a stand-alone feature that follows the spindle: it lowers when the spindle starts (M3) and rises when it stops (M5). Because it's separate from the tool changer logic, every tool changer – including manual tool change – can use it.

Logic types
Type 1 (1 valve), Type 2 (2 valves)
Sensor timeout
5 seconds
Override
MDI screen, while running

Dust hood

1. Manual override

The dust hood is enabled at power-up Dust hood enabled. You can disable it from the MDI screen at any time, including while machining Dust hood disabled – useful when a tool is too large for the hood, or to get a clear view of the cut.

2. Type 1 – single output

One output moves the hood up and down. The down sensor is optional – if it isn't assigned, MASSO skips the check.

FunctionSignal
Output: Dust Hood-1High = hood down, Low = hood up
Input: Dust Hood-1 (optional)High = hood down, Low = hood up
Dust Hood-1 output assignedDust Hood-1 input assigned
CommandSequence
M3 – hood downIf the dust hood is enabled in MDI, Output Dust Hood-1 goes High. MASSO waits up to 5 s for Input Dust Hood-1 High; otherwise Dust Hood Down Error.
M5 – hood upOutput Dust Hood-1 goes Low. MASSO waits up to 5 s for Input Dust Hood-1 Low; otherwise Dust Hood Up Error.
Dust Hood Down ErrorDust Hood Up Error

Type 1 wiring

Dust hood Type 1 wiring diagram

3. Type 2 – separate up and down outputs

Two outputs drive the hood down and up, with a sensor at each end.

FunctionSignal
Output: Dust Hood-1Move hood down
Output: Dust Hood-2Move hood up
Input: Dust Hood-1 (required)Hood down
Input: Dust Hood-2 (required)Hood up
Dust Hood-1 and -2 outputs assignedDust Hood-1 and -2 inputs assigned
CAUTION
Both Type 2 sensors are required and must be installed.
CommandSequence
M3 – hood downIf the dust hood is enabled in MDI, Output Dust Hood-1 goes High. MASSO waits up to 5 s for Input Dust Hood-1 High. If it doesn't arrive: Dust Hood Down Error and Output Dust Hood-1 goes Low. Once it arrives, Output Dust Hood-2 goes Low.
M5 – hood upOutput Dust Hood-1 goes Low. MASSO waits up to 5 s for Input Dust Hood-2 High. If it doesn't arrive: Dust Hood Up Error and Output Dust Hood-2 goes Low. Once it arrives, Output Dust Hood-2 goes Low.

Type 2 wiring

Dust hood Type 2 wiring diagram