MASSO G2 Drive and Relay wiring

INFORMATION: This describes the wiring of the A & B axis on the Masso G2. For wiring of the X, Y & Z axis on the Masso G2 refer to examples in the G3 Section of this documentation.

WARNING: Axis Step and Direction signals are common Ground and precautions must be taken to wire the controller to avoid any electrical damage to the system:

  • All axis outputs are common Gnd with +4 voltage signals.

  • Never short-circuit the signals with each other or any other voltage.

  • All signals must be isolated to other signals and connected directly to the drives

MASSO G2 A & B axis wiring examples

Teknic - ClearPath wiring

Gecko Drive 203V wiring

Gecko Drive G340 wiring

Gecko Drive G540 wiring

Leadshine Drive MX4660 wiring

Leadshine Drive CS-D1008 wiring

DM542A, DQ860MA wiring

Mitsubishi - MR-J3 wiring

Panasonic - MCDHT3520 wiring

Automation Technology Inc. - KL5056E wiring

Information: If you have a MASSO-G3 or are wiring the X, Y or Z axis on A MASSO-G2 please follow the link below.

MASSO G2 Relay wiring example

INFORMATION: All output signals can be easily inverted by selecting the input in the OUTPUTS list and pressing the space-bar key on the keyboard to invert the input signal. These settings are automatically saved.

CAUTION: The Maximum current on any relay output must not exceed 400mA or the output will be damaged.

Pin No.

Description

Type

Pin 1

Relay 1 - Function configurable through software

Open collector (Max load 400 mA)

Pin 2

Relay 2 - Function configurable through software

Open collector (Max load 400 mA)

Pin 3

Relay 3 - Function configurable through software

Open collector (Max load 400 mA)

Pin 4

Relay 4 - Function configurable through software

Open collector (Max load 400 mA)

Pin 5

Relay 5 - Function configurable through software

Open collector (Max load 400 mA)

Pin 6

Relay 6 - Function configurable through software

Open collector (Max load 400 mA)

Pin 7

Relay 7 - Output for E-Stop only

Open collector (Max load 400 mA)

INFORMATION: If using TTL outputs on the MASSO-G2 or you are using the Masso-G3 please follow the link below.